Caroflow Roof Drainage Products
CAROLET Refurbishment Outlets Specifications
The CAROLET body is manufactured in LM6 Aluminium Silicon casting alloy to BS EN 1706:2010 which is primed and then electrostatically coated with a protective polyester powder coating.
A fire retardant polystyrene insert is bonded to the underside void for insulation purposes.
The CAROLET Refurbishment outlet is compatible with pipework sizes; 75mm and 100mm diameter.
The codes and dimensions of each of the CAROLET outlets are as follows;
CAROLET Refurbishment Outlet to suit existing 75mm pipework
Code
– CL/75
A = 494, B = 354, C = 236, D = 50, E = 285, F = 63.5
CAROLET Refurbishment Outlet to suit existing 100mm pipework
Code
– CL/100
A = 494, B = 354, C = 236, D = 50, E = 285, F = 89
'MINI’ CAROLET Refurbishment Outlets
A ‘MINI’ version employs the same principles as its ‘Big Brother,’ but as the name implies is smaller in size for use in more restricted areas.
The ‘MINI’ CAROLET Refurbishment outlet is also compatible with pipework sizes; 75mm and 100mm diameter.
The codes and dimensions of each of the ‘MINI’ CAROLET outlets are as follows;
‘MINI’ CAROLET Refurbishment Outlet to suit existing 75mm pipework with insulation thickness of 35mm
Code
– CL/75/M35
A = 35, B = 276, C = 320, D = 182, E = 226, F = 63.5
‘MINI’ CAROLET Refurbishment Outlet to suit existing 75mm pipework with insulation thickness of 50mm
Code
– CL/75/M50
A = 50, B = 276, C = 320, D = 182, E = 226, F = 63.5
‘MINI’ CAROLET Refurbishment Outlet to suit existing 100mm pipework with insulation thickness of 35mm
Code
– CL/100/M35
A = 35, B = 276, C = 320, D = 182, E = 226, F = 89
‘MINI’ CAROLET Refurbishment Outlet to suit existing 100mm pipework with insulation thickness of 50mm
Code
– CL/100/M50
A = 50, B = 276, C = 320, D = 182, E = 226, F = 89
Useful Links
Technical Support
To request a quotation, hard copy literature or any further assistance, please call our sales department on (01763) 244446 or you can enquire using our online form.